5. 4 Reserators Coolant Circulation
1) The purpose of connecting the Jump Cable of the power supply’s main connector
(20P/24P) is to receive direct current (12V) needed for the test and leakage inspection.
2) Turn off all power of the PC and switch the Power Supply's ON/OFF button to OFF, connect
the enclosed Degassing Tube to the Reserator’s IN-OUT, and provide power to the AC cable.
3) Disconnect the power supply's main connector (20P/24P) and the CPU 4-Pin connector
from the motherboard, and connect the green wire terminal with the black wire terminal
with the use of Jump Cable.
4) Connect the Reserator’s DC cable connector to the power supply’s 4-Pin connector,
and provide power to the PC by switching the power supply's ON/OFF button to ON.
5) Blue LED will light up and the impeller located inside the Flow Indicator of the Reserator’s
front panel will begin to rotate when the power is supplied. (At this moment, let the
coolant circulate for approximately 30 seconds, then cut off the direct current and
wait for the impeller to stop. Once the impeller has come to a complete halt, you
must restart it in order to entirely eliminate the internal air. )
6) If the coolant is not circulating well due to internal air pressure during initial operation,
then tilt the Reserator by approximately 70and repeatedly turn the Reserator ON/OFF
with the Light/Reset button to completely release internal air trapped within the Reserator
body (must press the Reset button for longer than 5 seconds).
7) If the coolant is circulating properly, then turn of the power of the Power Supply, disconnect
the Degassing Tube, and disassemble the Quick Coupling Insert.
Note 1) Pay attention so that the coolant inside the Reservoir does not spill.
Note 2) Check the state of air release with the tube. If air is completely released, then turn
off the Power Supply and begin installing the water blocks.
Note 3) During coolant circulation, if the Flow Indicator fails to effectively sense the flux,
then the alarm will go off and the red LED will flicker. Press onto the Light/Reset
button for 5 seconds to reboot.
Quick Coupling
Insert
Degassing Tube
4-Pin Connecter
DC Cable Connecter
Main
Connecter
Motherboard
Power Connecter
Black Wire
Green Wire
Jump Cable
Light/Reset Button